banner
PHYSIO CARE DEVICES

GST : 07AUGPK3022J1ZT

Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm
Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm

Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm

Price 142000 INR/ Piece

MOQ : 1 Piece

Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm Specification

  • Material
  • Aluminum Alloy Housing
  • Technology
  • Semiconductor Diode Laser
  • Portable
  • Yes
  • Recyclable
  • No
  • Recommended For
  • Medical, Industrial, Scientific Research
  • Treatment
  • Laser Therapy, Laser Surgery, Materials Processing
  • Frequency Range
  • Continuous Wave (CW)
  • Usage
  • High power laser applications, treatment procedures, laboratory experiments
  • Age Group
  • Adult Use Only
  • Display
  • LCD Digital Display
  • Power Source
  • AC 110V/220V
  • Dimension (L*W*H)
  • 285 mm x 220 mm x 123 mm
  • Weight
  • 3.5 kg
  • Target Area
  • Soft Tissue (for medical), Various Materials (for industrial)
  • Fiber Connector
  • SMA905
  • Beam Mode
  • TEM00 (Single Mode)
  • Safety Features
  • Emission Indicator, Interlock System, Overheating Protection
  • Operation Mode
  • Continuous & Pulsed Mode
  • Spot Size
  • Adjustable (via fiber collimators)
  • Wavelength
  • 980 nm
  • Maximum Output Power
  • 20 watt
  • Emission Control
  • Key Switch, Emergency Stop, Foot Pedal Control
  • Cooling System
  • Integrated Forced Air Cooling
  • Laser Class
  • Class 4 (High Power/High Intensity)
 
 

About Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm


Feature Typical Specification
Wavelength 980nm 5nm
Output Power 20W CW or modulated up to 30kHz
Power Stability 3 over 2hours
MTTF 10000hours
Beam Divergence 3mrad full angle
Beam Diameter free space 58mm
Fiber Core Options 200m up to 1000m multimode
Fiber Connector FCPC FCAPC or SMA905
Modulation TTL Analog up to 30kHz
WarmUp Time 5 minutes
Ambient Temp Range 10C to 40C
Cooling TEC stabilizer optional heatsink radiatorc


Versatile Laser Applications

This high power laser is engineered for multifaceted use across the medical, industrial, and scientific sectors. It offers both continuous and pulsed operational modes, accommodating laser surgeries, therapies, material processing, and experimental procedures. The flexibility in spot size adjustment further enhances its applicability in delicate tasks or broad-surface treatments.


Robust Safety Mechanisms

Safety is paramount in the design of this Class 4 laser. It is equipped with an emission indicator, interlock system, emergency stop, key switch, and foot pedal control. These features work in tandem to ensure secure operation and quick shut-off, offering peace of mind for operators in high-intensity scenarios.


User-Friendly & Portable Design

With its lightweight construction (only 3.5 kg) and compact dimensions, this laser system is easily portable. The intuitive LCD digital display and ergonomic controls allow for straightforward setup and real-time monitoring. Its aluminum alloy housing ensures durability, making it suitable for demanding environments.

FAQ's of Class 4 High Power/High Intensity Laser 20 watt ,Wavelength 980nm:


Q: How is the Class 4 20W laser typically used in medical and industrial environments?

A: This high intensity laser is used for precise soft tissue treatment in medical fields, such as laser surgery and therapy, as well as for cutting, welding, or processing various materials in industrial applications. Its adjustable spot size and dual operational modes (continuous and pulsed) make it suitable for both targeted procedures and broader material processing tasks.

Q: What safety features protect users during operation of this high power laser?

A: Multiple safety mechanisms are integrated, including an emission indicator, interlock system, emergency stop button, key switch, and foot pedal control. Additionally, the system offers overheating protection to further mitigate operational risks.

Q: When should I use the continuous mode versus the pulsed mode on this laser?

A: Continuous mode is suitable for processes requiring consistent power delivery, such as steady material cutting or extended medical treatments. Pulsed mode is ideal where precise energy bursts are necessary, minimizing thermal impact or achieving localized effects, often required in delicate medical procedures or research experiments.

Q: Where can the 980nm, 20W laser be installed and used safely?

A: This portable laser is designed for use in professional environments such as hospitals, clinics, research laboratories, and industrial workshops. It should be operated only by trained adults, and proper protective equipment along with the built-in safety controls must be used at all times.

Q: What is the process for adjusting the laser spot size for various applications?

A: The spot size can be adjusted using compatible fiber collimators fitted to the device's SMA905 connector. This enables users to modify the focused area according to the specific medical, industrial, or laboratory requirement.

Q: Can this device be used for scientific research in addition to medical and industrial tasks?

A: Yes, the Class 4 20W laser is highly suitable for scientific research thanks to its stable beam profile (TEM00), adjustable output, and robust safety features. It facilitates advanced laboratory experiments that require controlled, high-intensity laser emissions.

Q: What are the main benefits of using this portable Class 4 laser system?

A: Key advantages include high output power for efficient processing, precision adjustment for versatile applications, comprehensive safety systems, ease of transport, and a user-friendly interface. These features collectively enhance productivity and operational safety in professional environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Advance physiotherapy equipment Category

whirpool bath therapy

whirpool bath therapy

Price 616000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Portable : No

Display : LCD

Technology : Digital

BTL-4625 Smart - 2 Channel Electrotherapy

BTL-4625 Smart - 2 Channel Electrotherapy

Price Range 92000.00 - 205000.00 INR

Minimum Order Quantity : 1 Piece

Portable : Yes

Display : Other, Large Color Touchscreen

Technology : Other, 2channel Electrotherapy



Back to top